Victron BlueSolar MPPT 150/35 12 V / 24 V / 36 V / 48 V
MPPT charge controller BlueSolar 150/35
- Battery voltage Automatic selection 12/24/36/48 V (a software tool is needed to select 36 V)
- Rated load current 35 A
- Maximum PV power 1a, b) 12V: 500W / 24V: 1000W / 36V: 1500W / 48V: 2000W
- maximum PV open circuit voltage 150 V absolute maximum in colder conditions
- 145 V in starting and running at peak
- Maximum efficiency 98%
- 0,0o1 consumption mA (1 uA)
- Charging voltage "absorption" Defaults: 14.4 / 28.8 / 43.2 / 57.6 V (adjustable)
- Charging voltage "float" Defaults: 13.8 / 27.6 / 41.4 / 55.2 V (adjustable)
- Multistage variable load algorithm
- Temperature compensation -16 mV / -32 mV / -68 mV / ° C
Protection
- Battery reverse polarity (fuse not accessible by the user)
- Reverse polarity PV
- Output short circuit
- overtemperature
- Operating temperature -30 to + 60 ° C (full rated output up to 40 ° C)
- Humidity 95%, non-condensing
- Data communication port
- VE.Direct
See the white paper on data communication on our website
CASE
- Color Blue (RAL 5012)
- Terminals 13 mm² / AWG6
- Type of protection IP43 (electronic components), IP22 (connection area)
- Weight 1.25 kg
- Dimensions (HxWxD) 130 x 186 x 70 mm
STANDARDS
- Safety EN / IEC 62109
- 1a) If more PV power is connected, the controller will limit the power input to the specified maximum.
- 1b) The PV voltage must exceed Vbat 5V (battery voltage) to boot the controller.
- Once started, the minimum PV voltage Vbat + 1V will.